Design And Construction Of Air Conditioner Containing Heat Pump

This project study is applicable to the field of heating and air conditioning. The design and construction of a split unit air conditioner with heat pump was carried out to achieve a suitable comfort in our home and office environment. After a study of existing air-conditioners and survey for availability of materials, the design concept of the split unit air-conditioner was achieved. And the following standard part were estimated as; compressor power rating 2.5hp, condenser power 8KW, evaporator power 5.85KW, power rating of blower as 120watts and heat pump of 100W. And with a working fluid of refrigerant R410A which is weak compared to refrigerant R22 but less hazardous to the environment. The split unit air conditioner was tested for conformance to specification and it was satisfactory.

CHAPTER ONE

1.0                                                        INTRODUCTION

1.1                                           BACKGROUND OF THE STUDY

Air conditioning is the process of altering the properties of air to favorable conditions, typically with the aim of distributing the conditioned air to an occupied space is to improve comfort whilst heat pump only produces heat which is mostly used during the time of cold. In the most general sense, air conditioning can refer to any form of technology humidification, de-humidification, heating, cooling, cleaning, ventilation, or air movement that modifies the condition of air [1-3]. In general, the air conditioner is a device that lowers the air temperature. The cooling is most done using a simple refrigeration cycle, but sometimes the evaporation is used, commonly for the comfort of cooling in buildings and motor vehicles [4-5]. In construction, a complete system of heating, ventilation and air conditioning is referred to as “HVAC” [6]. Air conditioning can also be provided by the simple process called free cooling which uses pumps to circulate a coolant (typically or a glycol mix) from a cold source, which in turn acts as a heat sink for the energy that is removed from the cooled space [7].

Generally, air conditioner can be classified into [8-9]; window unit air-conditioners, central unit air-conditioner, and split unit air-conditioner. In this air conditioner, all the component, namely; the compressor, condenser, expansion valve evaporator and cooling coil are enclosed in a single box. Window unit air conditioners are installed in an open window. The interior air is cooled as a fan blows it over the evaporator. On the exterior the heat drawn from the interior is dissipated into the environment as a second fan blows outside air over the condenser. A large house or building may have several such units, allowing each room to be cooled separately.

The central unit air conditioning unit is for cooling big building houses, offices, entire hotels, cinema hall, and factory etc. If the whole building is to be air condition, HVAC engineers find that putting individual units in each of the room is very expensive initially as well in the long run. The central air conditioning unit is comprises of huge compressor that has the capacity to produce hundreds of tons of air conditioning. The split unit air conditioning system comprises of three parts the outdoor unit, indoor unit and heat pump. The outdoor unit, fitted outside the room, house component like the compressor, condenser, and the expansion valve. The indoor unit comprises the evaporator, and cooling fan. The heat pump takes care of the heating of the environment. In the split system, one does not have to make any slot in the wall of the room.

However, considering the fact that Nigeria is located in a tropical region which is characterized by excessive high temperature and highly humid, it became necessary to develop a mechanical system which can help to reduce the hot the ambient temperature within a confined space for human comfort. In this research work, we carried out the design and construction of split unit air conditioner that contain heat pump.

1.1                                                   AIM OF THE PROJECT

The main aim of this work is to build an air conditioner with heat pump in mechanical engineering workshop.

1.2                                             OBJECTIVE OF THE PROJECT

The objectives of this work are:

  1. To build an air conditioner with heat pump
  2. To analyze calculations involved during the construction
  3. To study and understand working principle of an air conditioner.
  4. To analyze components of air condition.
  5. To analyze the operation and component of heat pump.

1.4                                              PURPOSE OF THE PROJECT

The purpose of this work is to setup a working and tested okay air conditioner which contain heat pump.

1.5                                         SIGNIFICANCE OF THE PROJECT

As a student of mechanical engineering, this work exposed me to working principle of an air conditioner, construction procedure and troubleshooting guide to help me address the most common problems you may encounter with your air conditioner. With this work I was able to explain how to build an air conditioner and its heat pump.

1.6                          APPLICATIONS OF THE PROJECT

Apart from academic purposes, this study can also be useful to:

  1. Ac producers,
  2. Ac users/ owners
  3. Ac technicians

2.0 INTRODUCTION:

This chapter provides the background and context of the research problems, reviews the existing literature on the Design And Construction Of Air Conditioner Containing Heat Pump, and acknowledges the contributions of scholars who have previously conducted similar research [REV2550] …

Document Information

  • Format: DOC/PDF
  • Title: Design And Construction Of Air Conditioner Containing Heat Pump:

YOU MAY LOVE THESE (Recommended)

Posted under:

To start a project on Repair And Rehabilitation Of A Faulty Air- Conditioner, follow these guidelines: In all types of air –conditioning work a through knowledge of basic principal is varying important. The report of the project “re pair and rehabilitation of a faulty Air–conditioner” serves as guide to project implementation. It explains and illustrates the import principle of operation and vario…

41 Pages 1 - 4 Chapters 5,057 Words DOC/PDF Format Instant Download UPN1586

Understand how to write the “Repair And Rehabilitation Of A Faulty Air Condition” Project

Posted under:

To develop a project on Repair And Rehabilitation Of A Faulty Air Condition, follow these approaches: The need for an authentic and reliable report relating to the repairs and rehabilitation of a faulty air-conditioner is inevitable. Many homes and offices uses the air-conditioner to cool he temperature in their respective homes. So the maintenance of the air-conditioner should be a top priority …

52 Pages 1 - 6 Chapters 5,502 Words DOC/PDF Format Instant Download UPN1585

Discover how to write the “Modification Of Proto-Type Air Conditioning Unit” Project

Posted under:

To undertake a project on Modification Of Proto-Type Air Conditioning Unit, follow these effective ways: The need for an authentic and reliable report relating to the modification of a proto-type air-conditioning unit is inevitable. Many homes and offices use the air conditioner to cool the temperature in their respective homes and offices, so the maintenance of the air conditioner should be a top p…

35 Pages 1 - 4 Chapters 4,002 Words DOC/PDF Format Instant Download UPN1153

Posted under:
INTRODUCTION The most common type of heat exchanger used in industry contains a number of parallel tubes enclosed in a shell and is thus called a shell and tube heat exchanger.  These heat exchangers are employed when a process required large quantities of fluid to be heated or cooled.  Due to their compact design, these heat exchangers contain a large amount of heat transfer area and also provide a high degree of heat transfer effici […]

88 Pages 1 - 5 Chapters 8,359 Words DOC/PDF Format Instant Download UPN1117

To write a project on Design And Construction Of An Automatic Water Pump Controller With Water Timed Flushing Mechanism, follow these structure: This project presents the concept of a control system into an automatic water pump controller. One of the motivations for this project is the need to bring a solution to the problem of water shortage in various places eliminating the major culprit, waste of water during pumping, dispensing into o…

65 Pages 1 - 5 Chapters 7,929 Words DOC/PDF Format Instant Download UPN4570

Learn the structure to write the “Construction Of Shell And Tube Heat Exchanger” Project

Posted under:

To carry out a project on Construction Of Shell And Tube Heat Exchanger, follow these effective methods: The aim of this project was to construct shell and tube heat exchanger with fixed boundless. A heat exchanger that would cool 5 x 5 x 10 – 3 kg/s of steam at a calculated heat load of 152 – 395/S was fabricated. The steam is to reach the heat exchanger from a distillation column at a temperature …

45 Pages 1 - 7 Chapters 5,507 Words DOC/PDF Format Instant Download UPN1102

To start a project on Construction Of An Automatic Solar Powered Water Level Regulated Water Pump, follow these guidelines: Electrical energy and water are two major things whose demands are very high globally. In order to meet these demands, the production of electrical energy has now been shifted more towards renewable sources of energy like solar. The crisis of water has also become a global concern. In this modern…

40 Pages 1 - 5 Chapters 5,325 Words DOC/PDF Format Instant Download UPN3776

Posted under:

To develop a project on Comparative Enthalpy Approach For Co- And Counter Current Flow In Concentric Tube Heat Exchanger, follow these approaches: The comparison Evaluation of a heat transfer coefficient between the counter current and co-current flow arrangement was carried out on heat trainer, fabricated in Nigeria. The experiments carried out are of two different arrangement; counter-current flow arrangement and co-current flow arrangeme…

114 Pages 1 - 5 Chapters 16,889 Words DOC/PDF Format Instant Download UPN2498

Posted under:
ABSTRACT In this paper, the insertion effect of a woven wire mesh to cross flow heat exchanger will be studied under steady state laminar flow conditions. 3-D numerical model was developed for the bare heat exchanger and the other wire mesh modules. The mesh wire diameter is 2.5 mm, porosity of 0.75, permeability of 10-10 and layer-to-l […]
Live Chat