Construction Of Automatic Change Over Switch

5 Chapters
|
43 Pages
|
5,965 Words

An automatic changeover switch, often referred to as an automatic transfer switch (ATS), is a critical component in electrical systems, seamlessly transferring power supply between the primary and secondary sources in the event of a power outage or fluctuations. This device plays a crucial role in ensuring uninterrupted power supply to essential loads, such as critical equipment or entire electrical systems, by automatically switching between the main power source and an auxiliary or backup source. The primary function of the automatic changeover switch is to detect any disruption in the main power supply and promptly shift the load to the backup source, preventing downtime and ensuring continuous operation. Its significance lies in its ability to enhance the reliability and efficiency of electrical systems, safeguarding against power interruptions and minimizing disruptions to various applications. The construction of an automatic changeover switch involves meticulous engineering to guarantee swift and reliable transitions between power sources, providing a seamless power supply experience.

TABLE OF CONTENT

Title Page
Certification
Dedication
Acknowledgement
Table Of Contents

 

Chapter One
1.0 Introduction

1.1 Back Ground
1.2 Aims/ Objectives
1.3 Scope Of Limitation
1.4 Definition Of Terms

Chapter Two
2.0 Literature Review

2.1 The Power Transformer
2.2 The Relay
2.3 Contactors
2.4 Switches
2.5 Capacitors
2.6 Diode
2.7 Indicator Lights (Light Emitting Diodes)
2.8 Circuit Breaker
2.9 Voltmeter
2.10 Power Supply

Chapter Three
3.0 Construction

3.1 Circuit Diagram
3.2 Block Diagram
3.3 Contactor Wiring Diagram
3.4 Diagram Of The Casing

Chapter Four
4.0 Testing And Evaluation

4.1 Testing
4.2 Evaluation
4.3 Trouble Shooting And Remedy
4.4 Maintainability

Chapter Five
5.0 Conclusion

Reference

CHAPTER ONE

1.0 INTRODUCTION
As the zeal for change over on public power supply and stand-by generator increases, Engineers have researched deep into the different ways and methods of achieving power change-over both manual and automatic types.
It may not be considered a serious issue in some places where supply is up-to 90% constant or where intermittent outage causes no great damage. However, places like the business centers, industrial areas, and even cold rooms need almost 100% power supply. So in this case there is need to provide a stand-by power supply in the event of power outage. The important thing is to make sure an effective stand-by power supply which is constant and reliable is provided to eliminate the problem of long time outage.
Before, this time, changeovers are operated manually, there by making it difficult for power continuity without a time wastage. This is because an operator must always be available at any point in time. This manually operated change-over switch has two switchable positions-(main and generator) an arm is also provided from where the operator can have access to the switching. Here, the effectiveness, i.e. the fastness of the switching anytime power needs to be changed is slow, and largely depends on the operator, which means that the system will be in-effective whenever the operator is not available.
The second generation of change over switch were made semi-automatic in which the main power supply directly powers the contactors. This arrangement is made in such a way that if the main power supply fails, the contactors will all drop, leaving the supply to the generator position. The effectiveness of the system will now depend on the operator to start the generator on time.
The main problem suffered by the manual and semi-automatic systems is that the operator must have to be continuously be on duty for it to be very effective. This depends on fully closed loop system to operate.
With more research by the scientists and engineers to improve on the earlier ones, the present day technology has made it possible for the change over switch to be more effective and fast with less labour more improvements has be made in terms of number of designs, using the closed loop system at feed back control. Some also use comparators, logic circuits and electronics timers to achieve the task.
The design of this project is in such a way that control or switching is done without any noticeable sign. It uses a combination of comparators digital switches (relays) and electromagnetic switches to achieve a very fast and effective change-over in the case of power failure. This type of switch does not depend on any operator to function well.

1.1 BACK GROUND
The background to this project work is traced to the in tense demand of the populace and industries, residential homes, and many more demand for change of power supply switch for effective and continuity of power supply without a notice interruption or delay in such process to any alternative supply if the main supply goes off.
Earlier to this time, such process is manually operated or not in used at all. The manual type which is always strenuous and time delayed was a little bit useful but not to a satisfactorily level. More level and expenses are always required to meet up with the time factor and effectiveness required of this process of change over. These expenses and labour could not be afforded by some individuals and industries that needed to practice this change over.
Regard to this solutions were suggested to improve the process, so the idea of change or transforming the manual operated to automatic was discovered and engineers went into work immediately and came up with this automatic change over switch. But the demand for this equipment was much that something must be done to meet up with increasing demand. But this increase in demand topples the decrease in supply due to the cost of securing this equipment. The students went into this project to find out how mass production could reduce the increase in demand or meet up with the demand. They now decide to go further single handedly produce this work and see how far it can be done without the help of industrial machine.
After the approval, we went into market survey and evaluation of the components, after a good study of the circuit diagram. The rating of the equipment was also considered. A lot of considerations were made based on the fluctuating nature and inconsistency of our main supply source. The cost of procuring the system was put together and found out that it is less cost, and easy in operation. The users can experience change over supply without an input or extra labour.
With all these considerations and studies we decided to put together this project.

1.2 AIMS / OBJECTIVES
The primary aim and objective of this project work among other things are:
a) To see how the problems of power change over can be solved with less capital and less labour.
b) To make sure that an average person can reach to the equipment by the evaluation of the cost of production of this project.
c) To check the effectiveness of this work and how fast it can work without risk or extra labour or shock to personnels.
It is also aimed at improving the availability of power supply at any point in time with this equipment, due to its automatic nature. This is because the automatic nature of this project makes it un noticeable at the out put or at the load.
This equipment when used will solve the problem of power outage suffered or delayed in change over suffered by many industries and business centres where power failure are greatly felt, and can cause a lot of regrets, because information are lost severally because of power failure, especially in business centres. This work therefore remedies these problems but can be regrettable.

1.3 SCOPE OR LIMITATION
The scope or range of this project work is as wide as 2.5KVA as the rating. This means that it is capable of with standing any input of the range from any source especially generator sets and can give an output of 220-230Volts.
With this rating of 2.5KVA and a voltage of 230Volts, this work can stand any load.
The limitation is within prescribed output /input range. In other words any increase in the input could cause some damage to the components.
Again, a circuit breaker was provided to protect the circuit from damage due to voltage surge or output fault or load fault.
The current rating is of 10.9Amps which is enough to withstand any load within the range.

1.4 DEFINITION OF TERMS
Generally, a change over switch is a system which could be manually or automatically operated, that changes one source of power supply to another source in the case of failure from either of the two sources.

SHARE PROJECT MATERIALS ON:

MORE DESCRIPTION:

Construction Of Automatic Change Over Switch:

An Automatic Change Over Switch, also known as an Automatic Transfer Switch (ATS), is an electrical device that automatically switches between two power sources to ensure uninterrupted power supply to a load. It is commonly used in applications where a backup power source, such as a generator or an alternate utility feed, is available to provide power in case the primary power source fails. Here are the key features and functions of an Automatic Change Over Switch:

  1. Dual Power Sources: An ATS typically connects to two power sources – the primary source (usually the mains utility power) and the secondary source (often a backup generator). The switch monitors the voltage and frequency of the primary power source.
  2. Automatic Switching: When the ATS detects a failure in the primary power source, such as a blackout or voltage drop below a preset threshold, it automatically switches the load from the primary source to the secondary source. This switchover is seamless and ensures continuous power supply to critical equipment.
  3. Manual Control: Many ATS units provide a manual mode that allows users to control the switching manually. This can be useful for maintenance or testing purposes.
  4. Time Delay: Some ATS units include a time delay feature, which prevents the switch from rapidly toggling back and forth between power sources if there are transient power fluctuations.
  5. Monitoring and Alarms: Modern ATS units often come with monitoring capabilities, allowing users to remotely monitor the status of the switch and power sources. They can also generate alarms or notifications in case of an automatic switchover.
  6. Load Management: ATS units may offer load shedding capabilities, which allow users to prioritize critical loads during a power outage, ensuring that essential equipment receives power while non-essential loads are temporarily disconnected.
  7. Synchronization: In applications where the backup power source is a generator, the ATS may include synchronization features to ensure a smooth transition and minimize power disruptions during the switch.
  8. Voltage and Frequency Matching: The ATS ensures that the secondary power source (e.g., generator) matches the voltage and frequency requirements of the load before making the switch.

ATS units are crucial in various settings, including data centers, hospitals, industrial facilities, and residential homes with backup generators. They help maintain business continuity and prevent damage to sensitive equipment during power outages or voltage fluctuations. The choice of an ATS should consider factors like load capacity, voltage compatibility, and the specific requirements of the application. Additionally, regular maintenance and testing of the ATS are essential to ensure its reliability when needed.