Design And Construction Of 3KVA Solar Power System

Overview

ABSTRACT

This work is on solar inverter converts direct current (DC) output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be fed into a commercial electrical grid or used by a local, off-grid electrical network. It is a critical balance of system (BOS)–component in a photovoltaic system, allowing the use of ordinary AC-powered equipment. Solar power inverters have special functions adapted for use with photovoltaic arrays, including maximum power point tracking and anti-islanding protection.

TABLE OF CONTENTS

TITLE PAGE

APPROVAL PAGE

DEDICATION

ACKNOWLEDGEMENT

ABSTRACT

TABLE OF CONTENT

CHAPTER ONE

1.0      INTRODUCTION

1.1      BACKGROUND OF THE PROJECT

1.2      PROBLEM STATEMENT

1.3      AIM AND OBJECTIVE OF THE PROJECT

1.4      SCOPE OF THE PROJECT

1.5     SIGNIFICANCE OF THE PROJECT

1.6      INVERTERS

1.6.1 Central Inverters

1.6.2 Micro Inverters

1.7      THE BALANCE OF SYSTEM (BOS)

1.8      SOLAR PANELS

1.8.1 Solar Panel Mono or Poly

CHAPTER TWO

2.0     LITERATURE REVIEW

2.1      INTRODUCTION

2.2         COMPONENTS USED FOR THE DESIGN

2.3          REVIEW OF THE RELATED STUDY

2.4      KNOWLEDGE GAP

CHAPTER THREE

3.0     DESIGN AND IMPLEMENTATION

3.1      INTRODUCTION

3.2      DESIGN SPECIFICATIONS

3.3      THE RELAY UNIT

3.4      BATTERY UNIT

3.5      BATTERY CHARGING UNIT

3.6      SOLAR PANNEL

3.7      OSCILLATOR STAGE

3.8       POWER SWITCHING MOSFET

3.9    CONTROL UNIT

3.10     SOFTWARE PART

3.11     DISPLAY UNIT

3.12     TEMPERATURE SENSOR

3.13     COMPLETE INVERTER CIRCUIT AND MODE OF OPERATION

CHAPTER FOUR

RESULT ANALYSIS

4.0      RESULTAND DISCUSSION

4.1      CONSTRUCTION AND TESTING

4.2      TESTING AND WORKABILITY OF THE INVERTER

4.3      RESULTS FROM TESTING

4.4      ASSEMBLING AND PACKAGING

4.5       SUMMARY OF RESULTS

CHAPTER FIVE

5.0      CONCLUSION

5.1      RECOMMENDATION

CHAPTER ONE

INTRODUCTION

1.1 Background

The solar inverter is a vital component in a solar energy system. It performs the conversion of the variable DC output of the Photovoltaic (PV) module(s) into a clean sinusoidal 50 or 60 Hz AC current that is then applied directly to the commercial electrical grid or to a local, off-grid electrical network. A solar cell (also called photovoltaic cell) is the smallest solid-state device that converts the energy of sunlight directly into electricity through the photovoltaic effect. A Photovoltaic (PV) module is an assembly of cells in series or parallel to increase voltage and/or current. A Panel is an assembly of modules on a structure. An Array is an assembly of panels at a site. Typically, communication support scheme is included so users can monitor the inverter and report on power and operating conditions, provide firmware updates and control the inverter grid connection.

At the heart of the inverter is a real-time microcontroller. The controller executes the very precise algorithms required to invert the DC voltage generated by the solar module into AC. This controller is programmed to perform the control loops necessary for all the power management functions necessary including DC/DC and DC/AC. The controller also maximizes the power output from the PV through complex algorithms called maximum power point tracking (MPPT). The PV maximum output power is dependent on the operating conditions and varies from moment to moment due to temperature, shading, cloud cover, and time of day so adjusting for this maximum power point is a continuous process. For systems with battery energy storage, the two controller can control the charging as well as switch over to battery power once the sun sets or cloud cover reduces the PV output power. (Aditee P. Bapatet al 2013)

1.2 Statement of Problem

If there is one factor that has perpetually maintained the status of Nigeria as a less developed country, it is its electricity sector. Till date, many households and industrial businesses cannot be guaranteed of 24 hours supply of electricity from the National grid. At this stage of Nigeria’s social and economic development, the country cannot deliver sufficient energy to the citizens despite huge financial resources that have been expended in the sector.

Rather, Nigerians have continued to rely on electricity generators for their power supply, fuel marketers are taking significant portion of households’ institutions of learning’and businesses’ incomes to supply power, noise pollution from regular humming generators have become integral part of living for many Nigerians with imaginable consequences on their health. The federal university of technology minna is not immune to the aforementioned problems of Nigeria’s power sector, which has led to increase in day to day running cost of the university. Because of these problems, there is a need to design and construct the hybrid solar panel inverter for the department of electrical and electronics, federal university of technology minna to complement or augment the electricity supply from the National grid, reduce cost of energy consumed and eliminate noise/environmental pollution that is associated with running of generator.

1.3 Aim and Objectives

The aim of this project is to design and construct an efficient and economical 3000-Watthybrid solar inverter that will utilize the appropriate use of office electrical appliances.

The objectives are as follows: –

  • (i) To provide efficiency, steadiness in the use of power appliances, by ensuring continuous availability of power supply in the cause of main outage during an execution of an important or urgent assignment. Thereby enabling the department meet up with its office duties even when central power is not available.
  • (ii) Reduce load on the National grid that turn to be reduce the overall energy consumption dependency on the main energy supply in the country
  • (iii) Decrease customer utility bill on energy utilization because of its non-fuel consumption, low price and maintenance cost as compared to the convectional sources of power supplies within International and Local market.
  • (iv) Again, reduce carbon discharges and subsequently reduce global warming particularly in a period when poor climatic change has become a threat to human survival and life in general to all living creatures hence an ever increasing concern to control it.

1.4 Scope of Study

Basically, solar power source makes it possible to provide a clean reliable and quality supply of alternative electricity free of surges orsags which could be found in the line voltage frequency (50Hz). This project design aims at creating a 3000watts power source which can be utilized as a regular power source for private individuals in the office or at home. This project involves the design and construction of a 3000Watt hybrid Solar PV (photovoltaic) system which involves a solar panel, car battery and an inverter. Furthermore, as a consumer is generating his or her own electricity they also will benefit from a reduction in their electricity bills.

1.5 Significance of the Project

The solar inverter is the second most significant (and second most expensive) component of a solar PV system. It’s important because it converts the raw Direct Current (DC) solar power that is produced by the solar panels into Alternating Current (AC) power that comes out of the wall sockets outlet. Inverters also have technology that maximizes the power output of that DC energy.

The use of solar power has many advantages. Firstly, the energy from the sun is free and readily accessible in most parts of the world. Moreover, the sun will keep shining until the world’s end. Also, silicon from which most photovoltaic cells are made is an abundant and nontoxic element (the second most abundant material in the earth’s crust).

Secondly, the whole energy conversion process is environmentally friendly. It produces no noise, harmful emissions or polluting gases. The burning of natural resources for energy can create smoke, cause acid rain and pollute water and air. Carbon dioxide, CO2, a leading greenhouse gas, is also produced in the case of burning fuels. Solar power uses only the power of the sun as its fuel. It creates no harmful by-product and contributes actively to the reduction of global warming.

1.6 Inverters

The inverter takes direct current DC power from the charged battery bank and converts it to sinusoidal alternating current AC power for the typical household or office lights and appliances. Once the number of watt-hours required for a day is determined, the peak loads need to be ascertained to properly size the inverter. This is the amount of watts used based on all appliances and loads that will be running at one time. A slit star air conditioner is an example of what may be the peak load requirement for office as case study. A 1/2 HP (horse power) split air conditioner will use about 1490 (adjusted) watts per hour. If this represents the total peak loads for an office as the case study, an inverter that will be able to supply at least 1490 watts of continuous power from the battery bank; let’s assume one in the 1500-watt range will be required. It is a smart idea to begin the system with the size of inverter you plan to develop into, as upgrading to newer, larger models is expensive. (Pure Energies 2014)

There are two basic types of inverters.

1.6.1 Central Inverters Central inverters are well-tested and reliable systems that have been around for decades. These are the most common types of inverters. With central inverters, every solar panel is wired in a “string” to the inverter box. The conversion from DC to AC occurs at one central location, such as a garage.Because the solar panels are wired in “series,” each panel’s power output depends on all of the panels working. For example, In a string of Christmas tree lights. If one bulb goes out, the whole string of lights goes out until the bad bulb is replaced. So, if shade from a tree covers one panel, it can seriously diminish the power produced by the whole solar system until the shade clears. This is reason accurate shade analysis is so important.

1.6.2 Micro Inverters

Micro inverters are relatively new to solar. Instead of converting the DC to AC power at a central location, micro inverters are installed right under each solar panel. The main advantage to micro inverters is the ability for each solar panel to transmit power into the house independently. In other words, each panel produces its own solar power and keeps producing out solar watts regardless of what happening to the panel beside it. The down side of micro inverters is that they can be more expensive and take more labour cost to replace each inverter. Also, because they are so new, micro inverter reliability is unproven outside of laboratory testing. (Pure Energies 2014)

1.7 The Balance of System (BOS)

There are many other less well known and less expensive parts to a solar system. Installers typically wrap these up into “Balance of System” or “The BOS”

The balance of system includes components such as wiring, emergency DC disconnects, system monitoring hardware, the frames or “racking” that holds your panels to the roof and at the right angle, nuts, bolts, roof “flashing” to prevent leaks, and more. (Pure Energies 2014)

1.8 Solar Panels

Generally, Solar Panels are used for charging batteries. They provide a good solution for those that want to be self-sufficient and go on long camping missions through remote areas. They are available in various voltage and power ratings. More than one solar panel can be used in parallel to combine their power output. Solar panels joined in parallel work most efficiently if they are the same. If they are the same, you can design it so that they both generate power at their optimal

operating points. Mixing different panels together gives a compromised operating point. It will work but the panels will not operate as efficiently.

1.8.1 Solar Panel Mono or Poly

Silicon solar panels have two basic construction methods – polycrystalline or monocrystalline. There are slight differences between poly and mono cells. Mono are slightly more expensive, require more energy to make, and are slightly more efficient. Poly are slightly cheaper, use less energy to make so are better for the environment, are slightly less efficient but have a slightly better temperature coefficient. That means at elevated temperatures the poly cells become more efficient.

The differences are only slight. It is largely irrelevant. A solar panel with good efficiency and good temperature coefficient is to be used whether it is poly or mono, it does not matter.

CHAPTER FIVE

CONCLUSION AND RECOMMENDATION

5.1 CONCLUSION

This thesis was designed and constructed to provide an alternative means of power supply for domestic and commercial uses. In addition, it aimed to provide solution to the epileptic nature of power supply in this country.This inverter can supply power to most household appliances for a period of time that is directly proportional to the ampere-hour rating of the battery. Finally, to achieve a longer time of power supply, battery banks and wider solar modules are recommended.

5.2 RECOMMENDATION

  1. The inverter should be design to use more than two batteries at a time connected in parallel.
  2. The charging unit should be designed to be able to deliver a high charging current, so that batteries could be charged on time.
  3. The device should be incorporated with alarm, to call the attention of the user when battery discharged.
  4. The device should be design to automatically switch OFF when battery charges are below the useable capacity.

Chapter Two: Literature Review

2.0 INTRODUCTION:

This chapter provides the background and context of the research problems, reviews the existing literature on the Design And Construction Of 3KVA Solar Power System, and acknowledges the contributions of scholars who have previously conducted similar research [REV66473] …

Document Information

    • Format: DOC/PDF
    • Title: Design And Construction Of 3KVA Solar Power System:

YOU MAY LOVE THESE (Recommended)

  • To start a project on Use Of Manpower Audit For Efficient Man Power Planning, follow these guidelines: The purpose of this research is to investigate on the use of manpower audit for efficient manpower planning in Enugu State Broadcasting Service. In carrying out the research, the researcher used such instrument as questionnaires, interviews and published work to obtain all the relevant data requi…

    89 Pages 1 - 5 Chapters 10,155 Words DOC/PDF Format Instant Download UPN62714

  • Techniques for writing the “Study Of Impact Of Frequency Deviation On Power System” Project

    To develop a project on Study Of Impact Of Frequency Deviation On Power System, follow these approaches: The operation and the development of power system networks introduce new types of stability problems.  The effect of the power generation and consumption on the frequency of the power system can be described as a demand/generation imbalance resulting from a sudden increase/decrease in the demand …

    62 Pages 1 - 5 Chapters 11,700 Words DOC/PDF Format Instant Download UPN65119

  • To undertake a project on Solar Technology, An Alternative Source Of Energy For National Development, follow these effective ways: This research was carried out to understand solar technology: An alternative source of energy for national development. The study was based on the pursuance of basic objectives to ascertain the present state of power generation and supply in Nigeria, to examine the possibility of reviving the ene…

    52 Pages 1 - 5 Chapters 10,044 Words DOC/PDF Format Instant Download UPN64084

  • To write a project on Design And Fabrication Of A Solar Powered Digital Street Clock, follow these structure: The design of the PIC microcontroller LED clock consists of few components that implement a solar powered digital street clock using LED display pattern. In this paper the LED clock was designed with 12 red LEDs in the outer circle, 12 green LEDs in the inner circle and four centralized yellow LE…

    42 Pages 1 - 5 Chapters 7,536 Words DOC/PDF Format Instant Download UPN66087

  • Guide for writing the “Solar Outdoor Surveillance CCTV Camera” Project

    To carry out a project on Solar Outdoor Surveillance CCTV Camera, follow these effective methods: The implementation and use of an outdoors solar powered surveillance (Closed Circuit Television technology) in societies across the globe has become a standard and reliable way of securing out environment. Solar powered outdoors surveillance CCTV camera is a solar-powered wireless smart camera ne…

    50 Pages 1 - 5 Chapters 7,823 Words DOC/PDF Format Instant Download UPN66152

  • To start a project on Role Of Marketing Research In Enhancing Customer Service Level In The Power Industry, follow these guidelines: Marketing research in now giving position in the solving or organisation problems, both private and public owned organisations. The importance of marketing reach to organisation cannot be over emphasised. Organisation as an open system cannot operate in isolation, they must react to environment (…

    42 Pages 1 - 5 Chapters 4,755 Words DOC/PDF Format Instant Download UPN64279

  • Techniques for writing the “Problems Of Manpower Development In Government Parastatals” Project

    To develop a project on Problems Of Manpower Development In Government Parastatals, follow these approaches: The focus of this research work is on the problem of manpower development in government parastatals with special reference to Enugu State Marketing Company which is the case study. The researchers presents the introductory part of the write-up which dealt with the historical background of Enugu S…

    76 Pages 1 - 5 Chapters 9,260 Words DOC/PDF Format Instant Download UPN62197

  • To undertake a project on Power Supply And The Performance Of Small And Medium Scale Industries, follow these effective ways: This research work centers on the power supply and the performance of small and medium scale industries in Nigeria from 1986 – 2010. carrying out this study, secondary data were collected and empirical analysis was made to achieve these objectives, multiple regression were used in anglicizing the…

    66 Pages 1 - 5 Chapters 6,988 Words DOC/PDF Format Instant Download UPN63880

  • Steps for writing the “Power Amplifier” Project

    INTRODUCTION Power amplifier is an electronic device, which is used to increase sound energy. In other words, the final stage which must driven a given load e.g mechanical indicator, a loudspeaker cathode roy tade, magnetic deflection coil, a transmitting accrual of a communication network. Power amplifier is also used in regulation power supplies, chopper amplifier, motor controller etc. In general the load will by its nature, demand […]

    38 Pages 1 - 5 Chapters 3,996 Words DOC/PDF Format Instant Download UPN63998

  • To write a project on Integration Of Renewable Energy Resources For Electric Power Supply In A Developing Economy Using Pv, Wind Energy, Biomass And Tidal Energy Interfacing With 330Kv Or Standalone, follow these structure: Nowadays renewable energy plays a great role in power system around the world. The continuous growth in overall energy demand and the related environmental impacts play a significant role in the large sustainable and green global energy transition. Moreover, the electrical power sector is a major…

    100 Pages 1 - 5 Chapters 39,477 Words DOC/PDF Format Instant Download UPN66469

Live Chat