Design And Construction Of A 35Kva Power Inverter Inbuilt Charger, Over And Under Voltage Control, Temperature Control, Microcontroller Based And Digital Display

Overview

ABSTRACT

This project is titled the design and construction of a DC to AC inverter system. It is designed to meet up with the power demand in the offices and in homes in the absence of power supply from the national supply authority, NEPA. In order words the device / item serves as a substitute for NEPA which almost monopolises the power supply to people.

It is designed in such a way that it will take up 12v DC from battery and inverts it to an output of 230v, 50Hz AC. It makes no noise during operation and no hazardous carbon monoxide is generated in the surrounding.   

This is a feature that makes it safe to use any where when compared to generator. Also, the circuit is capable of charging the battery (i.e 12v source) when the power from the supply authority is on. This greatly reduces the cost of operation of the system.

This work is aimed at designing a modified sine wave inverter that can be used to power appliances both in homes and industries.

TABLE OF CONTENTS

TITLE PAGE

APPROVAL PAGE

DEDICATION

ACKNOWLEDGEMENT

ABSTRACT

TABLE OF CONTENT

CHAPTER ONE

1.0      INTRODUCTION

1.1      OBJECTIVE OF THE PROJECT

1.2      SIGNIFICANCE OF THE PROJECT

1.3    APPLICATION OF THE PROJECT

1.4      SCOPE OF THE PROJECT

1.5      LIMITATION OF THE PROJECT

1.6      PURPOSE OF THE PROJECT

1.7      PROJECT ORGANIZATION

CHAPTER TWO

2.0     LITERATURE REVIEW

2.1      REVIEW OF HISTORY OF AN INVERTER

2.2   REVIEW OF HOW TO CHOOSING THE RIGHT INVERTER

2.3      REVIEW OF THE DIFFERENCE BETWEEN SINE WAVE AND MODIFIED SINE WAVE   INVERTER.

2.4      REVIEW OF INVERTER CAPACITY

2.5      SAFETY OF INVERTER

2.6      INVERTER RATING

2.7      WHY CHOOSE A MODIFIED SINE WAVE INVERTER?

2.8      TYPES OF INVERTER

CHAPTER THREE

3.0     CONSTRUCTION

3.1      BASIC DESIGNS OF AN INVERTER

3.2      BLOCK DIAGRAM OF THE SYSTEM

3.3      SYSTEM OPERATION

3.4      CIRCUIT DIAGRAM

3.5      CIRCUIT DESCRIPTION

3.6     DESCRIPTION OF COMPONENTS USED

3.7      HOW TO CHOOSE A RIGHT INVERTER AND BATTERY

3.8      HOW TO CHOOSE THE BEST INVERTER BATTERY

CHAPTER FOUR

RESULT ANALYSIS

4.0      CONSTRUCTION PROCEDURE AND TESTING

4.1      CASING AND PACKAGING

4.2      ASSEMBLING OF SECTIONS

4.3      TESTING OF SYSTEM OPERATION

4.4      COST ANALYSIS

CHAPTER FIVE

5.0      CONCLUSION

5.1      RECOMMENDATION

5.2      REFERENCES

 CHAPTER ONE

1.0                                            INTRODUCTION

A power inverter converts DC power (also known as direct current), to standard AC power (alternating current). Inverters are used to operate electrical equipment from the power produced by a car or boat battery or renewable energy sources, like solar panels or wind turbines. DC power is what batteries store, while AC power is what most electrical appliances need to run so an inverter is necessary to convert the power into a usable form. For example, when a cell phone is plugged into a car cigarette lighter to recharge, it supplies DC power; this must be converted to the required AC power by a power inverter to charge the phone.

In modified sine wave, The waveform in commercially available modified-sine-wave inverters is a square wave with a pause before the polarity transition, which only needs to cycle through a three-position switch that outputs forward, off, and reverse output at the pre-determined frequency. The peak voltage to RMS voltage does not maintain the same relationship as for a sine wave. The DC bus voltage may be actively regulated or the “on” and “off” times can be modified to maintain the same RMS value output up to the DC bus voltage to compensate for DC bus voltage variation.

The ratio of on to off time can be adjusted to vary the RMS voltage while maintaining a constant frequency with a technique called PWM. Harmonic spectrum in the output depends on the width of the pulses and the modulation frequency. When operating induction motors, voltage harmonics is not of great concern, however harmonic distortion in the current waveform introduces additional heating, and can produce pulsating torques.

  • OBJECTIVE OF THE PROJECT

The objective of this project is to design and construct a 3.5kva modified sine wave inverter which can be powered from the source of 12V battery to produce an output of 230vac. This inverter composed of inbuilt charger, over and under voltage control, temperature control, microcontroller based with digital display.

1.2                                           PURPOSE OF THE PROJECT

The purpose of this work is to design an electronic device or circuitry that changes direct current (DC) to alternating current (AC). The input voltage (12vdc), output voltage (230vac) and frequency (50hz), and overall power handling depend on the design of the specific device or circuitry. The inverter does not produce any power; the power is provided by the DC source.

A typical power inverter device or circuit requires a relatively stable DC power source capable of supplying enough current for the intended power demands of the system. The input voltage depends on the design and purpose of the inverter. Examples include: 12 VDC, for smaller consumer and commercial inverters that typically run from a rechargeable 12 V lead acid battery.

The waveform of this work is modified sine wave. The modified sine wave output of such an inverter is the sum of two square waves one of which is phase shifted 90 degrees relative to the other. The result is three level waveform with equal intervals of zero volts; peak positive volts; zero volts; peak negative volts and then zero volts. This sequence is repeated. The resultant wave very roughly resembles the shape of a sine wave.

1.3                                       SIGNIFICANCE OF THE PROJECT

In the recent years,  power  inverter has become a major power source due to its environmental and economic benefits and proven reliability. Since the solar power system does not have moving parts, virtually it does not require any kind of maintenance once installed.

Power inverter is produced by connecting the device on the 12VDC battery as the input to produce 230VAC as the required output. It can also be connected to solar panel.

Second, the whole energy conversion process is environmentally friendly. It produces no noise, harmful emissions or polluting gases. The burning of natural resources for energy can create smoke, cause acid rain and pollute water and air. Carbon dioxide, CO2, a leading greenhouse gas, is also produced in the case of burning fuels. Power inverter uses only the power of the battery as its fuel. It creates no harmful by-product and contributes actively to the reduction of global warming.

1.4                                              SCOPE OF THE PROJECT

Power inverter converts fixed direct current (DC) voltage to frequency sinusoidal alternating current (AC) voltage output.

Power inverters are used to power and control the speed, torque, acceleration, deceleration, and direction of the motor. The use of inverter has become prevalent in wide range of industrial applications; from motion control applications to ventilation systems, waste water processing facilities to machining areas, and many others. Though power inverters offer lower operating costs and higher efficiency, they are not without their problems.

1.5                                         LIMITATION OF THE PROJECT

  • Expensive when compared to traditional generators
  • There are no large capacity inverter in the markets
  • The inverter can power a few appliances for a short period
  • The input is limited to 12VDC, output to 230VAC and the frequency to 50Hz
  • The power rating of the work is 3.5kva

1.6                                       APPLICATION OF THE PROJECT

The applications and uses of a power inverter which are as follows:

DC power source utilization

Inverter designed to provide 230 VAC from the 12 VDC source provided in an automobile. The unit shown provides more than 20 amperes of alternating current, or enough to power upto 5KW load.

An inverter converts the DC electricity from sources such as batteries, solar panels, or fuel cells to AC electricity. The electricity can be at any required voltage; in particular it can operate AC equipment designed for mains operation, or rectified to produce DC at any desired voltage.

Uninterruptible power supplies

An uninterruptible power supply (UPS) uses batteries and an inverter to supply AC power when main power is not available. When main power is restored, a rectifier supplies DC power to recharge the batteries.

Induction heating

Modified Sine wave Inverters convert low frequency main AC power to higher frequency for use in induction heating. To do this, AC power is first rectified to provide DC power. The inverter then changes the DC power to high frequency AC power.

HVDC power transmission

With HVDC power transmission, AC power is rectified and high voltage DC power is transmitted to another location. At the receiving location, an inverter in a static inverter plant converts the power back to AC. The inverter must be synchronized with grid frequency and phase and minimize harmonic generation.

Variable-frequency drives

A variable-frequency drive controls the operating speed of an AC motor by controlling the frequency and voltage of the power supplied to the motor. An inverter provides the controlled power. In most cases, the variable-frequency drive includes a rectifier so that DC power for the inverter can be provided from main AC power. Since an inverter is the key component, variable-frequency drives are sometimes called inverter drives or just inverters.

VFDs that operate directly from an AC source without first converting it to DC are called cyclo-converters. They are now commonly used on large ships to drive the propulsion motors.

Electric vehicle drives

Adjustable speed motor control inverters are currently used to power the traction motors in some electric and diesel-electric rail vehicles as well as some battery electric vehicles and hybrid electric highway vehicles.

Air conditioning

An inverter air conditioner uses a variable-frequency drive to control the speed of the motor and thus the compressor.

Electroshock weapons

Electroshock weapons and tasters have a DC/AC inverter to generate several tens of thousands of V AC out of a small 12 V DC battery. First the 12VDC is converted to 400–2000V AC with a compact high frequency transformer, which is then rectified and temporarily stored in a high voltage capacitor until a pre-set threshold voltage is reached. When the threshold (set by way of an air gap or TRIAC) is reached, the capacitor dumps its entire load into a pulse transformer which then steps it up to its final output voltage of 20–60 kV. A variant of the principle is also used in electronic flash and bug zappers, though they rely on a capacitor-based voltage multiplier to achieve their high voltage.

1.7                                        PROJECT WORK ORGANIZATION

The various stages involved in the development of this project have been properly put into five chapters to enhance comprehensive and concise reading. In this project thesis, the project is organized sequentially as follows:

Chapter one of this work is on the introduction to a power inverter. In this chapter, the background, significance, objective limitation and problem of a power inverter were discussed.

Chapter two is on literature review of a power inverter. In this chapter, all the literature pertaining to this work was reviewed.

Chapter three is on design methodology. In this chapter all the method involved during the design and construction were discussed.

Chapter four is on testing analysis. All testing that result accurate functionality was analyzed.

Chapter five is on conclusion, recommendation and references.

Chapter Two: Literature Review

2.0 INTRODUCTION:

This chapter provides the background and context of the research problems, reviews the existing literature on the Design And Construction Of A 35Kva Power Inverter Inbuilt Charger, Over And Under Voltage Control, Temperature Control, Microcontroller Based And Digital Display, and acknowledges the contributions of scholars who have previously conducted similar research [REV65424] …

Document Information

    • Format: DOC/PDF
    • Title: Design And Construction Of A 35Kva Power Inverter Inbuilt Charger, Over And Under Voltage Control, Temperature Control, Microcontroller Based And Digital Display:

YOU MAY LOVE THESE (Recommended)

  • To start a project on Use Of Manpower Audit For Efficient Man Power Planning, follow these guidelines: The purpose of this research is to investigate on the use of manpower audit for efficient manpower planning in Enugu State Broadcasting Service. In carrying out the research, the researcher used such instrument as questionnaires, interviews and published work to obtain all the relevant data requi…

    89 Pages 1 - 5 Chapters 10,155 Words DOC/PDF Format Instant Download UPN62714

  • To develop a project on Temperature And Water Requirement For Leaching of Caustic Alkalt From “NGU”, follow these approaches: The production and analysis of “Ngu” extract for temperature and water requirement for leaching of casuistic alkali is the basic objective of this project. The production was carried out by using unit operations and also using the female inflorescence of a palm fruit (Eleasis Guineesis) as raw ma…

    47 Pages 1 - 7 Chapters 5,369 Words DOC/PDF Format Instant Download UPN62925

  • Writing strategies for the “Study Of Impact Of Frequency Deviation On Power System” Project

    To undertake a project on Study Of Impact Of Frequency Deviation On Power System, follow these effective ways: The operation and the development of power system networks introduce new types of stability problems.  The effect of the power generation and consumption on the frequency of the power system can be described as a demand/generation imbalance resulting from a sudden increase/decrease in the demand …

    62 Pages 1 - 5 Chapters 11,700 Words DOC/PDF Format Instant Download UPN65119

  • To write a project on Design And Fabrication Of A Solar Powered Digital Street Clock, follow these structure: The design of the PIC microcontroller LED clock consists of few components that implement a solar powered digital street clock using LED display pattern. In this paper the LED clock was designed with 12 red LEDs in the outer circle, 12 green LEDs in the inner circle and four centralized yellow LE…

    42 Pages 1 - 5 Chapters 7,536 Words DOC/PDF Format Instant Download UPN66087

  • To carry out a project on Role Of Marketing Research In Enhancing Customer Service Level In The Power Industry, follow these effective methods: Marketing research in now giving position in the solving or organisation problems, both private and public owned organisations. The importance of marketing reach to organisation cannot be over emphasised. Organisation as an open system cannot operate in isolation, they must react to environment (…

    42 Pages 1 - 5 Chapters 4,755 Words DOC/PDF Format Instant Download UPN64279

  • To start a project on Problems Of Manpower Development In Government Parastatals, follow these guidelines: The focus of this research work is on the problem of manpower development in government parastatals with special reference to Enugu State Marketing Company which is the case study. The researchers presents the introductory part of the write-up which dealt with the historical background of Enugu S…

    76 Pages 1 - 5 Chapters 9,260 Words DOC/PDF Format Instant Download UPN62197

  • To develop a project on Power Supply And The Performance Of Small And Medium Scale Industries, follow these approaches: This research work centers on the power supply and the performance of small and medium scale industries in Nigeria from 1986 – 2010. carrying out this study, secondary data were collected and empirical analysis was made to achieve these objectives, multiple regression were used in anglicizing the…

    66 Pages 1 - 5 Chapters 6,988 Words DOC/PDF Format Instant Download UPN63880

  • Writing strategies for the “Power Amplifier” Project

    INTRODUCTION Power amplifier is an electronic device, which is used to increase sound energy. In other words, the final stage which must driven a given load e.g mechanical indicator, a loudspeaker cathode roy tade, magnetic deflection coil, a transmitting accrual of a communication network. Power amplifier is also used in regulation power supplies, chopper amplifier, motor controller etc. In general the load will by its nature, demand […]

    38 Pages 1 - 5 Chapters 3,996 Words DOC/PDF Format Instant Download UPN63998

  • Writing strategies for the “Patient Heartbeat And Temperature Monitor” Project

    INTRODUCTION 1.1 BACKGROUND Heart beat rate means the number of heartbeats per unit time, usually expressed as beats per minute (bpm). The human heart pounds to pump oxygen rich blood to the muscles and carry cell waste products away from the tissues. Heartbeat rate can vary according to the demand of the muscles to absorb oxygen and excrete carbon dioxide changes such as during exercise or sleep. It also varies significantly between i […]

    64 Pages 1 - 6 Chapters 6,536 Words DOC/PDF Format Instant Download UPN63900

  • To undertake a project on Microcontroller Based Portable Paramedic Blood Warmer for Transfusion, follow these effective ways: The primary objective of this project is to warm stored blood using a warmer that adjusts to the patient’s body temperature. Maintaining temperature is critical for safe patient care, as errors can result in life-threatening conditions. The human body’s normal temperature is 37.5 °C, whereas bloo…

    74 Pages 1 - 5 Chapters 11,799 Words DOC/PDF Format Instant Download UPN89919

Live Chat