Geoelectric Imaging Of Groundwater Pollution

Case Study Of PTI Dumpsite

56 Pages 1 – 5 Chapters8,237 WordsDownload Complete Material

The Geoelectric Imaging Of Groundwater Pollution Complete Project Material (PDF/DOC)

Abstract

A resistivity survey was made in some part of PTI dumpsite in order to determine the quality of the ground water in that area. The survey consisted of 5 electrical soundings which were carried out using the Schlumberger array configuration with a current electrode separation of 126m. The data was interpreted by computer aided iteration techniques using the Resistivity modeling Software Application. The result of the interpretation shows four to five distinct geoelectric layers with resistivity ranging from 112.7Ωm to 426.8Ωm.  Difference in apparent resistivity was assumed to be due only to differences in specific conductance of groundwater in the saturated zone. The result of the survey has shown that the aquifer in the study area has not yet being contaminated.

Chapter One

1.0 Introduction
1.1 Background Of Study
Groundwater is commonly understood to mean water occupying all the voids within a geologic stratum. Groundwater is one of the nation’s most valuable natural resources. It is the source of about 40 percent of the water used for all purposes exclusive of hydropower generation and electric power plant cooling. Surprisingly for a resource that is so widely used and so important to health and to the economy of the country, the occurrence of ground water is not only poorly understood but is also, in fact, the subject of many widespread misconceptions. Common misconception includes the belief that ground water occurs in underground rivers resembling surface streams whose presence can be detected by certain individuals. These misconceptions and others have hampered the development and conservations of ground water and have adversely affected the protection of its quality. Groundwater occurs everywhere but sometimes its availability in economic quantity depends solely on the distribution of the subsurface geomaterials that are referred to as the aquifers. This implies that where groundwater is not potentially endowed enough, there may be either complete lack or inadequacy due to increasing industrial and domestic needs.
Pollution occurs when the concentration of various chemical or biological constituents exceed a level at which a negative impact on amenities, the ecosystem, resources and human health can occur. Pollution results primarily from human activities. There are different sources of pollution. When they are chemical or biological constituents creating pollution they are known as contaminants. Contaminants degrade the natural quality of a substance or medium. It can either be organic or inorganic.
Surface resistivity methods have been employed successfully for detecting and mapping ground-water contamination under a variety of conditions. The method is based on the fact that formation resistivity depends on the conductivity of the pore fluid as well as the properties of the porous medium. Under favorable conditions, contrasts in resistivity may be attributed to mineralized groundwater with a higher than normal specific conductance originating at a contamination source. Success with surface resistivity methods depends to a large extent on a good knowledge of subsurface conditions. Conditions favorable for delineating zones of contamination include uniform subsurface conditions, a shallow groundwater table, and good electrical contrast between mineralized and natural water.
One of the primary problems in field investigations of groundwater pollution is locating the contaminant plume. In most cases, the goal is to positively locate the pollutant and its movement by test holes and direct monitoring. In the interest of efficiency the investigative areas should be as focused as possible. In many cases a general knowledge of local hydrogeology allows a reasonable initial estimate of pollutant direction; in other instances even this may be lacking. Drilling of sampling holes on a hit-or-miss basis is both time-consuming and expensive. It can also be destructive to the property involved. Under certain subsurface conditions, surface geoelectrical profiling can quickly and cheaply locate the general location of the plume and identify areas most feasible for sampling and monitoring.
Numerous investigations have established the usefulness of surface electrical resistivity as a tool in the detection of ground water contamination.

1.1 Definition and Causes of groundwater pollution
Pollution has been found to be much more widespread than we had believed only a few years ago. Polluted ground water may pose a serious threat to health. Pollution of ground water refers to any deterioration in quality of the water resulting from the activities of man. Most pollution of ground water results from the disposal of wastes on the land surface, in shallow excavations including septic tanks, use of fertilizers, leak in sewers and pipelines. The magnitude of any pollution problem depends on the size of the area affected and the amount of the pollutant involved, the solubility, toxicity, and density of the pollutant, the mineral composition and the hydraulic characteristics of the soils and rocks through which the pollutant moves, and the effect or potential effect on ground-water use.

1.2 STATEMENT OF PROBLEM
Here this study focuses mainly on the impact of Groundwater pollution in a dump site area and how it can be evaluated using resistivity method. But first I will like to discuss briefly about the impact of pollution on Groundwater before giving reasons of using resistivity method on ground water pollution in a dump site.

1.3 AIM AND OBJECTIVES
The aim of this work is to detect, delineate and denominate the extent of contaminant intrusion on ground water in an area, with the following objectives in mind:

  • To study the geo electrical properties of the sub surface to depth in other to estimate contamination degree.
  • To uncover the direction of pollutant flow relative to the ground water flow.
  • To assess and map the vertical and lateral extent of contaminated groundwater into sub surface and how much ground water area it covered.
  • To distinguish between polluted and non – polluted zones with respect to the groundwater contamination.

1.4 SIGNIFICANCE OF STUDY
The significance of the above study is important in following ways:

  • It will provide useful information on the condition of ground water at dump site areas which can serve as a useful tool in environmental impact assessment (EIA), of that area.
  • Information about water flow direction will assist in the design of efficient and cost-effective monitoring networks and remediation strategies of ground water pollution.
  • Geoelectric details of the subsurface gotten from this study will give sound knowledge of the sub surface geology including infiltration and percolation process is prerequisite for managing contaminant transport in the saturated or aquifer zone…..
Chapter Two

2.0 LITERATURE REVIEW
2.1 Introduction

The chapter presents a review of related literature that supports the current research on the Geoelectric Imaging Of Groundwater Pollution, systematically identifying documents with relevant analyzed information to help the researcher understand existing knowledge, identify gaps, and outline research strategies, procedures, instruments, and their outcomes

How To Download Complete Material (PDF/Doc)

This Research Work On “Geoelectric Imaging Of Groundwater Pollution” Complete Material Can Be Downloaded Through Whatsapp, Email Or Download Link. Click The Below Button To Proceed:

Disclamer:

This study on the Geoelectric Imaging Of Groundwater Pollution is solely for academic research purposes only and should be used as a research guideline or source of ideas. Copying word-for-word or submitting the entire project work to your school is unethical academic behavior and “UniProjects” is not part of it.