Design And Construction Of Star-Delta Of 3-Phase Motor With Forward And Reverse Run Operation Control

Overview

ABSTRACT

This work is on the forward reverse star delta electric motor control using switches. Moving ac motor clockwise and anticlockwise has many applications in the present technology, such as in our garage doors. Some garage door motors are easily reversed AC motors and geared down. Forwarding and reversing of an ac motor is done using a push button switches.

Depending on the choice of the operator, starting the circuit is selected via the forward or the reverse push button switches. When the forward push button switch is selected, the command is transferred to the relevant forward function of the circuit which activates the forward main coil (blue). The relevant auxiliary contacts of the forward main coil (blue) would then be actuated opposite its normal state, that is, a normally open contact would eventually switch to a close contact whereas a normally close contact would switch to an open contact.

 CHAPTER ONE

1.1                                                        INTRODUCTION

An AC motor converts electrical energy into mechanical energy. The reverse of this would be the conversion of mechanical energy into electrical energy and is done by an electric generator.

Motors are used to produce linear or rotary force (torque), and should be distinguished from devices such as magnetic solenoids and loudspeakers that convert electricity into motion but do not generate usable mechanical powers, which are respectively referred to as actuators and transducers.

Most AC motors are started directly on line, but when very large motors are started that way, they cause a disturbance of voltage on the supply lines due to large starting current surges. To limit the starting current surge, large induction motors are started at reduced voltage and then have full supply voltage reconnected when they run up to near rotated speed.

Voltage reduction during star-delta starting is achieved by physically reconfiguring the motor. During starting the motor windings are connected in star configuration and this reduces the voltage across each winding. This also reduces the torque by a factor of three.

The motor is required to start. To provide the maximum available torque, the motor is started in ‘star’, which provides a supply of 230volts to each of the windings (providing high current to each winding).

Once the motor is running, it is running in an inefficient mode, due to the use of a high current supply, which will (if left) cause the motor to overheat.

Three phase induction motors, also called asynchronous motors, are most extensively used motors in industries because of certain advantages like self starting, robust design, simple construction, less maintenance, efficient and comparatively low cost, though there is a problem of peak starting current associated with these motors. Peak starting current can be up to 5 to 7 times of full load current (flc) and sometimes it may become as high as 10 times of flc. However, the problem of peak starting current remains only for few seconds till the motor attains its speed, this problem may become severe especially with the motors above 10 HP. To deal with the problem of peak starting current or inrush current associated with three phase induction motors, many different starters having different mechanism and principle of operation are used. Star-delta starters are used for motors ranges from 5 hp or 3.5 kW. Star delta starters first configure windings of 3 phase motors in star thereby reduce voltage across each winding and then after few seconds these starters configure windings in delta and motors start run at full load voltage without any difficulty.

The forward and backward of an AC motor control is very important because of both local and industrial application. This work discus how three phase Motor will rotate in two directions viz forward and Reverse.

1.2                                             OBJECTIVE OF THE PROJECT

The objective of this work is to design the Forward and Reverse controlling of an ac motor using star-delta connection for three phase motor.

1.3                                                 SCOPE OF THE PROJECT

The Star Delta starting method is a motor starting mechanism that minimizes the large amount of starting current that motors draw in. The Star Delta, as the name suggests basically involves feeding the motor with 1/sq.root3 (58%) of the full load current until it attains speed then applying the full load current. This method is commonly referred to as “Soft Starting” the motor, For this to work the whole set-up requires 3 contactor i.e The Star Contactor, The Delta Contactor and The Main Contactor. However for the motor to be started in Star Delta, its internal connection at the terminal box has to be wired in Delta-giving it capability of receiving the full-load current at any instant.
1.4                                         SIGNIFICANCE OF THE PROJECT

  • With these work, a three phase motor can move Forward and Reverse direction
  • The operation of the star-delta method is simple and rugged
  • It is relatively cheap compared to other reduced voltage methods.
  • Good Torque/Current Performance.
  • It draws 2 times starting current of the full load ampere of the motor connected

1.5                                           LIMITATION OF THE PROJECT

  1. Low Starting Torque (Torque = (Square of Voltage) is also reduce).
  2. Break In Supply – Possible Transients
  3. Six Terminal Motor Required (Delta Connected).
  4. It requires 2 set of cables from starter to motor.
  5. It provides only 33% starting torque and if the load connected to the subject motor requires higher starting torque at the time of starting than very heavy transients and stresses are produced while changing from star to delta connections, and because of these transients and stresses many electrical and mechanical break-down occurs.
  6. In this method of starting initially motor is connected in star and then after change over the motor is connected in delta. The delta of motor is formed in starter and not on motor terminals.
  7. Applications with a load torque higher than 50 % of the motor rated torque will not be able to start using the start-delta starter.
  8. Low Starting Torque: The star-delta (wye-delta) starting method controls whether the lead connections from the motor are configured in a star or delta electrical connection. The initial connection should be in the star pattern that results in a reduction of the line voltage by a factor of 1/√3 (57.7%) to the motor and the current is reduced to 1/3 of the current at full voltage, but the starting torque is also reduced 1/3 to 1/5 of the DOL starting torque.
  9. The transition from star to delta transition usually occurs once nominal speed is reached, but is sometimes performed as low as 50% of nominal speed which make transient Sparks.

1.6                                FEATURES OF STAR-DELTA CONNECTION

For low- to high-power three-phase motors.

  1. Reduced starting current
  2. Six connection cables
  3. Reduced starting torque
  4. Current peak on changeover from star to delta
  5. Mechanical load on changeover from star to delta

1.7                                  APPLICATION OF STAR-DELTA MOTOR

Industries are using forward and reverse ac motor solutions for process, control of devices such as ac conveyor

Consumer products including electronic toys, home security, gate and garage door openers also make use of this device.

1.8                                 COMPONENTS OF STAR-DELTA MOTOR

Star-delta motor Consists following units

  1. Contractors (Main, star and delta contractors)
  2. Time relay (pull-in delayed) 1 No.
  3. Three-pole thermal over-current release
  4. Fuse elements or automatic cut-outs for the main circuit
  5. Fuse element or automatic cut-out for the control circuit

Chapter Two: Literature Review

2.0 INTRODUCTION:

This chapter provides the background and context of the research problems, reviews the existing literature on the Design And Construction Of Star-Delta Of 3-Phase Motor With Forward And Reverse Run Operation Control, and acknowledges the contributions of scholars who have previously conducted similar research [REV65353] …

Document Information

    • Format: DOC/PDF
    • Title: Design And Construction Of Star-Delta Of 3-Phase Motor With Forward And Reverse Run Operation Control:

YOU MAY LOVE THESE (Recommended)

  • To start a project on Training And Development Of Human Resource In Banking Operation, follow these guidelines: This research work is aimed at finding the effect of training and development banking operation. The purpose is to determine the relationship between the level productivity and human resources training and development in union bank PLC which is the case study. It also discovers the causes of high…

    77 Pages 1 - 5 Chapters 9,449 Words DOC/PDF Format Instant Download UPN62704

  • To develop a project on Stock Control As A Management Tools For Efficient And Effective Stores Operation, follow these approaches: Stock control had been a neglected function in an organization due to the fact that most organization both public and private sectors lacks the professionals in the field who are capable of carrying out a good stock system. This work titled ‘’stock control as a management tools for effective and …

    66 Pages 1 - 5 Chapters 7,642 Words DOC/PDF Format Instant Download UPN62894

  • Writing strategies for the “Personnel Safety In Stores Operation In An Organization” Project

    To undertake a project on Personnel Safety In Stores Operation In An Organization, follow these effective ways: The researcher undertook an in-depth research work on personnel safety in stores operation. In chapter one, the researcher gave a concise historical background of the company under study. Whereby there is a concise insight on the role and contribution of Camela Vegetable Oil Limited towards the a…

    76 Pages 1 - 5 Chapters 9,431 Words DOC/PDF Format Instant Download UPN62812

  • Steps for writing the “Operation And Maintenance Of Steam Boiler” Project

    To write a project on Operation And Maintenance Of Steam Boiler, follow these structure: The steam boiler is to control specification problem, to illustrate how the evolving algebra approach to the specification and the verification of complex system can be exploited for a reliable and well documented development of executable but formally inspectableand systematically modifiable cod…

    45 Pages 1 - 6 Chapters 5,037 Words DOC/PDF Format Instant Download UPN64202

  • Guide for writing the “Online Motor Vehicle Licensing System” Project

    To carry out a project on Online Motor Vehicle Licensing System, follow these effective methods: Motor vehicle administration is a composite process and revolves around the management and the control of motor licensing. Vehicle licensing is the payment of a fee for the use of motor vehicle on public roads. Vehicle licensing in Nigeria began over 100 years ago starting from the colonial admin…

    78 Pages 1 - 5 Chapters 2,837 Words DOC/PDF Format Instant Download UPN63046

  • INTRODUCTION 1.1       BACKGROUND TO THE STUDY Insurance is a provision of a system of compensation for loss, damage, sickness, death and other unbearable circumstances in return for regular payment of a pre-determined premium. Insurance companies are important for both businesses and individuals as they indemnify the losses and put them in the same positions as they were before the occurrence of the loss. Insurers also provide econo […]

    74 Pages 1 - 5 Chapters 10,901 Words DOC/PDF Format Instant Download UPN82755

  • INTRODUCTION 1.1 BACKGROUND OF THE STUDY The stores function is a vial part of industrial concerns, public & private utility undertaking agricultural enterprises, maniple authorities, aimed service and government department and it must be design to suit the needs of the organization it services. There, is therefore, no standard system which can be universally recommended or applied but, in this course of time, certain principles an […]

    40 Pages 1 - 4 Chapters 4,991 Words DOC/PDF Format Instant Download UPN62811

  • 1.1 INTRODUCTION In the 17th century when farming was regarded as he main occupation in Nigeria, farmers go to the farm in the morning, in the evening they gather at the village square to eat drink, rest and plan how to tackle their farming activity of the following day. This necessitated the building of small house outside their main house as a place of rest and to accommodate visitors who may be travelling and need a place of rest. A […]

    84 Pages 1 - 5 Chapters 8,514 Words DOC/PDF Format Instant Download UPN63734

  • To start a project on Investigation Into The Operation Of Different Transport Agency, follow these guidelines: This project is based on Investigation into the operation of different transport agency in Kwara Express, Young Legacy, Kasmag and Emirate service Questionnaires and oral interview method of data collections were adopted, in which about 100 questions are distributed and oral interview carried out…

    47 Pages 1 - 5 Chapters 6,348 Words DOC/PDF Format Instant Download UPN64171

  • To develop a project on Impact Of Fuel Subsidy Removal On The Operation Of Small Scale Business, follow these approaches: This research which is a modest attempts to study the impact of removal of fuel subsidy has been systematical surveyed and analyze by the researcher. The researcher selected some firms as a study and reviewed some impacts that exist within removal of fuel subsidy, its effect in Nigeria citizens. …

    61 Pages 1 - 5 Chapters 8,058 Words DOC/PDF Format Instant Download UPN62304

Live Chat